Energies (Apr 2022)

Voltage Readjustment Methodology According to Pressure and Temperature Applied to a High Temperature PEM Fuel Cell

  • Mathieu Baudy,
  • Olivier Rondeau,
  • Amine Jaafar,
  • Christophe Turpin,
  • Sofyane Abbou,
  • Mélanie Grignon

DOI
https://doi.org/10.3390/en15093031
Journal volume & issue
Vol. 15, no. 9
p. 3031

Abstract

Read online

The operating conditions can have uncontrolled effects on the voltage of a High-Temperature Proton Exchange Membrane Fuel Cell (HT-PEMFC). For instance, the HT-PEMFC can be used at ambient pressure, i.e., without having a back pressure regulator. In this case, the variation in the atmospheric pressure directly affects pressures inside the fuel cell, which induces voltage variation. Moreover, in transient phases, several coupled phenomena can have an uncontrolled effect on the voltage. For example, following a change in the current operating point, thermal conditions in the fuel cell can vary, and the temperature stabilization then leads to a voltage variation. This article introduces a readjustment method for the fuel cell voltage to compensate for the effects of the pressure and temperature variations that are undergone and to decouple their effects. This methodology is based on the realization of a design of experiments to characterize the voltage sensitivity to pressure ([1; 1.5 bar]) and temperature ([120; 180 °C]) between 0.2 and 1 A/cm2 of an Advent PBI MEA (formerly BASF Celtec®-P 1100 W). The data obtained allowed identifying an empirical model that takes into account the aging caused by the experiment. Finally, the methodology is criticized before proposing an alternative method.

Keywords