Ventilation failure after lateral jackknife positioning for robot-assisted lung cancer surgery in a patient after lingula-sparing left upper lobectomy

  • Izumi Kawagoe,
  • Masakazu Hayashida,
  • Daizoh Satoh,
  • Kenji Suzuki,
  • Eiichi Inada

DOI
https://doi.org/10.1186/s40981-018-0188-8
Journal volume & issue
Vol. 4, no. 1
pp. 1 – 4

Abstract

Read online

Abstract Background Ventilation failure commonly occurs when a standard left-sided double-lumen tube is used in patients after left upper lobectomy having remarkable angulation of the left main bronchus. We present a female without remarkable angulation, in whom ventilation failure occurred after lateral jackknife positioning. Case presentation A 73-year-old female after lingula-sparing left upper lobectomy without remarkable angulation was scheduled for robot-assisted right upper lobectomy. Ventilation failure with a standard left-sided double-lumen tube occurred when she was placed not in the lateral position but in the lateral jackknife position required for robotic surgery. After replacement by the Silbroncho® left-sided double-lumen tube, adequate one-lung ventilation became possible. Conclusions Ventilation failure with a standard tube may occur more easily when patients with bronchial angulation are placed in the lateral jackknife than lateral position due to posture-induced exacerbations of bronchial angulation. The Silbroncho® tube seems useful in such situations.

Keywords