Applied Sciences (Feb 2022)

Application of Frequency Response Analysis Method to Detect Short-Circuit Faults in Three-Phase Induction Motors

  • Salem Mgammal Al-Ameri,
  • Ahmed Allawy Alawady,
  • Mohd Fairouz Mohd Yousof,
  • Muhammad Saufi Kamarudin,
  • Ali Ahmed Salem,
  • Ahmed Abu-Siada,
  • Mohamed I. Mosaad

DOI
https://doi.org/10.3390/app12042046
Journal volume & issue
Vol. 12, no. 4
p. 2046

Abstract

Read online

The industry has widely accepted Frequency Response Analysis (FRA) as a reliable method to detect power transformers mechanical deformations. While the FRA technique has been recommended in recent literature as a potential diagnostic method to detect internal faults within rotating machines, detailed feasibility studies have not been fully addressed yet. This paper investigates the feasibility of using the FRA technique to detect several short circuit faults in the stator winding of three-phase induction motors (TPIMs). In this regard, FRA testing is conducted on two sets of induction motors with various short circuit faults. Investigated faults include short circuits between two phases, short circuit turns within the same phase, phase-to-ground, and phase-to-neutral short circuit. The measured FRA signatures are divided into three frequency ranges: low, medium, and high. Several statistical indicators are employed to quantify the variation between faulty and healthy signatures in each frequency range. Experimental results attest the feasibility of the FRA technique as a diagnostic tool to detect internal faults in rotating machines, such as induction motors.

Keywords