npj Materials Degradation (Aug 2023)
The impact of minor Cr additions in low alloy steel on corrosion behavior in simulated well environment
Abstract
Abstract Low alloy steel samples with different Cr content (0‒3 wt%) have been exposed to simulated well environment. It is revealed that the 3%Cr sample initially has the highest corrosion resistance. However, due to faster formation of a FexCayCO3 protective scale in the 0%Cr sample, this sample demonstrates the highest corrosion resistance after 2 days of exposure. While the FexCayCO3 scale is also formed in the 1%Cr sample, the scale is weakly adhered and porous, which does not enable good corrosion resistance. Although the scale formation is delayed in a sample with 3 wt%Cr, once it is formed, the presence of Cr-rich phase in this scale provides greater long-term corrosion protection. Localized corrosion attack is observed in the samples with 0% Cr and 1%Cr, whereas the 3%Cr sample shows no sign of localized attack due to initial pre-passivation and the ability to rebuild the protective scale.