Journal of Orthopaedic Surgery and Research (Jan 2019)

Pedicle screw loosening: the value of radiological imagings and the identification of risk factors assessed by extraction torque during screw removal surgery

  • Xiaoliang Wu,
  • Jiawei Shi,
  • Jinyan Wu,
  • Yongquan Cheng,
  • Kaiwen Peng,
  • Jianting Chen,
  • Hui Jiang

DOI
https://doi.org/10.1186/s13018-018-1046-0
Journal volume & issue
Vol. 14, no. 1
pp. 1 – 9

Abstract

Read online

Abstract Background context Pedicle screw loosening is a common complication after spine surgeries. Traditionally, it was assessed by radiological approaches, both X-ray and CT (computed tomography) scan, while reports using mechanical method to study screw loosening after spine surgery are rare. The primary objective was to study the prevalent of pedicle screw loosening according to extraction torque during screw removal surgery and access the sensitivity and specificity of both X-ray and CT scan for diagnosing screw loosening. The second objective was to identify the risk factors for low extraction torque of pedicle screw that might lead to loosening. Methods Thirty-three patients who underwent pedicle screw removal surgery after at least 2 years from primary surgery were evaluated preoperatively for fixation stability by X-ray and CT scan. In total, 236 screws were taken out, and the extraction torque data was recorded and analyzed to identify the sensitivity and specificity of both imaging studies for screw loosening. Furthermore, risk factors that might contribute to low extraction torque were also studied. Results The mean extraction torque of removed screws was 1.55 ± 1.00 Nm; a torque force of less than 1.02 Nm was used to define a screw as loosened. According to such criterion, the loosening rate was found to be 33%. X-ray had a sensitivity of 24% and a specificity of 98%, while CT scan had a sensitivity of 22% and a specificity of 96%. Extraction torque of pedicle screws inserted in fractured vertebrae was significantly lower than those in non-fractured vertebrae (p = 0.009); meanwhile, screws of non-fusion surgery had lower extraction torque when compared to those in fusion surgery (p = 0.001). BMD (bone mineral density) and age had low but significant linear relationship with screw extraction torque (p = 0.01, R 2 = 0.304; p = 0.045, R 2 = 0.123). Conclusions Our findings showed that both X-ray and CT scan had high specificity for screw loosening detection, but their sensitivities were relatively low. Surgeons needed to be more cautious when assessing screw loosening merely according to radiological examination, and aware of that screws in fractured vertebrae or non-fusion surgery were vulnerable to loosening.

Keywords