BMC Ophthalmology (Aug 2021)

Evaluation of the efficacy, safety, and stability of posterior chamber phakic intraocular lenses for correcting intractable myopic anisometropic amblyopia in a pediatric cohort

  • Fathy Fawzy Morkos,
  • Nader F. Fawzy,
  • Mohamed El Bahrawy,
  • Nada Fathy,
  • Rania Serag Elkitkat

DOI
https://doi.org/10.1186/s12886-021-02074-3
Journal volume & issue
Vol. 21, no. 1
pp. 1 – 9

Abstract

Read online

Abstract Background Myopic anisometropic amblyopia in pediatrics is one of the most challenging clinical situations that can face an ophthalmologist. Conventional correction modalities for myopic anisometropia, using spectacles, contact lenses, and/or occlusion therapy, may not be suitable for some pediatric patients or for some ocular conditions. This may lead to the development of anisometropic amblyopia. The aim of the present study was to evaluate the visual and the refractive efficacy, safety, and stability of Posterior Chamber Phakic Intraocular Lenses (PC-pIOLs) for correcting myopic anisometropic amblyopia in a pediatric cohort. Methods This case series, prospective, interventional study was conducted at Watany Eye Hospital, Cairo, Egypt. It comprised children and teenagers with myopic anisometropic amblyopia and unsuccessful conventional therapy. After implantation of Intraocular Collamer Lenses “ICLs” (Visian ICL, Model V4c, STAAR Surgical, Monrovia, California, USA), postoperative follow-up visits were scheduled, with automated refraction and Pentacam imaging performed. Results The study enrolled 42 eyes of 42 patients. The age range was 3 to 18 years (mean ± SD = 10.74 years ±4.16). The mean preoperative spherical equivalent (SE) was − 12.85 D ± 2.74. The results declared a significant improvement in the postoperative Corrected Distance Visual Acuity “CDVA” (P value < 0.01) and SE (P value < 0.01). The efficacy index had a value of 1.18 ± 0.3 and the safety index was 1.09 ± 0.24. The follow-up visits had a mean ± SD of 14.67 months ±16.56 (range of 1 to 54 months). The results showed a refractive stability, with statistically insignificant improvements in the patients’ visual acuity and refractive status on evaluating the enrolled pediatrics during the follow-up visits compared to the first postoperative visits. No postoperative complications were encountered. Worthy of mention is that there was a significant (80%) non-compliance with the prescribed postoperative occlusion therapy. Conclusions The present study, with the longest reported follow-up range, declared the long-term efficacy, safety, and stability of Visian ICLs for correcting myopic anisometropic amblyopia in pediatrics. The reported non-compliance with occlusion therapy validates the early implantation of Visian ICLs in cases with failed conventional therapy to guard against anisometropic amblyopia.

Keywords