Ciência Rural (Oct 2008)

Métodos de extrusão manual e elétrica dos espermat��foros de reprodutores selvagens do camarão-rosa Farfantepenaeus paulensis (Decapoda: Penaeidae) Manual and electrical spermatophore extrusion methods of the pink shrimp Farfantepenaeus paulensis (Decapoda: Penaeidae) wild broodstock

  • Cintia Nakayama,
  • Silvio Peixoto,
  • Diogo Lopes,
  • Gustavo Vita,
  • Dariano Krummenauer,
  • Geraldo Foes,
  • Ronaldo Cavalli,
  • Wilson Wasielesky

DOI
https://doi.org/10.1590/S0103-84782008000700034
Journal volume & issue
Vol. 38, no. 7
pp. 2018 – 2022

Abstract

Read online

O presente estudo comparou os métodos manual e elétrico de extrusão do espermatóforo do camarão-rosa Farfantepenaeus paulensis com o objetivo de verificar se os métodos de extrusão exercem influência na quantidade de células espermáticas e na regeneração de novos espermatóforos. Os machos foram extrusados no início (dia zero) e no final do experimento (dia 43) para verificação da eficiência dos métodos no processo de regeneração. A extrusão manual foi realizada por meio de pressão na região do quinto par de pereiópodos e o método elétrico com uso de eletrodo para transmissão de impulso elétrico de 9 volts na mesma região. Os dois métodos foram considerados eficientes, não sendo encontradas diferenças significativas entre estes (P>0,05) para o número de células espermáticas. Entretanto, foi verificada, no final do experimento, a perda de peso corporal, peso de espermatóforo e menor índice espermatossomático (IES) (PThe present study compared manual and electrical methods to extrude the spermatophore of the pink shrimp Farfantepenaeus paulensis aiming to analyze their influence on the number of spermatic cells and spermatophore regeneration. The males were extruded in the beginning (day zero) and in the end (43rd day) of the experiment to evaluate the efficiency of these methods in the regeneration process. For the extrusion, a gentle pressure was applied manually in the fifth pair of pereiopods or electrically by a 9 volt pulse in the same area. Both methods were efficient in removing the spermatophore and no significant differences were found (P>0.05) in the number of sperm cells. Nevertheless, significant decreases (P<0.05) in the body weight, spermatophore weight and spermatosomatic index (ESI) at the end of the experimental period were observed by using the electrical stimulation. The mean values (±SD) of the number of sperm cells were 1.46 (±0.84) and 3.25 (±2.12) millions for the electrical and manual treatments, respectively. Results indicate that both methods may be applied to collect initial samples of spermatophores as well as for sperm quality testing. However, when previously spermatophore-extruded males are to be used, the manual method is indicated as the number of spermatic cells, spermatophore weight, body weight, and ESI are maintained after regeneration.

Keywords