PLoS Medicine (Jul 2017)

Cerebrovascular pressure reactivity monitoring using wavelet analysis in traumatic brain injury patients: A retrospective study.

  • Xiuyun Liu,
  • Joseph Donnelly,
  • Marek Czosnyka,
  • Marcel J H Aries,
  • Ken Brady,
  • Danilo Cardim,
  • Chiara Robba,
  • Manuel Cabeleira,
  • Dong-Joo Kim,
  • Christina Haubrich,
  • Peter J Hutchinson,
  • Peter Smielewski

DOI
https://doi.org/10.1371/journal.pmed.1002348
Journal volume & issue
Vol. 14, no. 7
p. e1002348

Abstract

Read online

BackgroundAfter traumatic brain injury (TBI), the ability of cerebral vessels to appropriately react to changes in arterial blood pressure (pressure reactivity) is impaired, leaving patients vulnerable to cerebral hypo- or hyperperfusion. Although, the traditional pressure reactivity index (PRx) has demonstrated that impaired pressure reactivity is associated with poor patient outcome, PRx is sometimes erratic and may not be reliable in various clinical circumstances. Here, we introduce a more robust transform-based wavelet pressure reactivity index (wPRx) and compare its performance with the widely used traditional PRx across 3 areas: its stability and reliability in time, its ability to give an optimal cerebral perfusion pressure (CPPopt) recommendation, and its relationship with patient outcome.Methods and findingsFive hundred and fifteen patients with TBI admitted in Addenbrooke's Hospital, United Kingdom (March 23rd, 2003 through December 9th, 2014), with continuous monitoring of arterial blood pressure (ABP) and intracranial pressure (ICP), were retrospectively analyzed to calculate the traditional PRx and a novel wavelet transform-based wPRx. wPRx was calculated by taking the cosine of the wavelet transform phase-shift between ABP and ICP. A time trend of CPPopt was calculated using an automated curve-fitting method that determined the cerebral perfusion pressure (CPP) at which the pressure reactivity (PRx or wPRx) was most efficient (CPPopt_PRx and CPPopt_wPRx, respectively). There was a significantly positive relationship between PRx and wPRx (r = 0.73), and wavelet wPRx was more reliable in time (ratio of between-hour variance to total variance, wPRx 0.957 ± 0.0032 versus PRx and 0.949 ± 0.047 for PRx, p = 0.002). The 2-hour interval standard deviation of wPRx (0.19 ± 0.07) was smaller than that of PRx (0.30 ± 0.13, p ConclusionswPRx offers several advantages to the traditional PRx: it is more stable in time, it yields a more consistent CPPopt recommendation, and, importantly, it has a stronger relationship with patient outcome. The clinical utility of wPRx should be explored in prospective studies of critically injured neurological patients.