BMC Family Practice (Sep 2010)

Excluding pulmonary embolism in primary care using the Wells-rule in combination with a point-of care D-dimer test: a scenario analysis

  • Lucassen Wim AM,
  • Douma Renée A,
  • Toll Diane B,
  • Büller Harry R,
  • van Weert Henk CPM

DOI
https://doi.org/10.1186/1471-2296-11-64
Journal volume & issue
Vol. 11, no. 1
p. 64

Abstract

Read online

Abstract Background In secondary care the Wells clinical decision rule (CDR) combined with a quantitative D-dimer test can exclude pulmonary embolism (PE) safely. The introduction of point-of-care (POC) D-dimer tests facilitates a similar diagnostic strategy in primary care. We estimated failure-rate and efficiency of a diagnostic strategy using the Wells-CDR combined with a POC-D-dimer test for excluding PE in primary care. We considered ruling out PE safe if the failure rate was Methods We performed a scenario-analysis on data of 2701 outpatients suspected of PE. We used test characteristics of two qualitative POC-D-dimer tests, as derived from a meta-analysis and combined these with the Wells-CDR-score. Results In scenario 1 (SimpliRed-D-dimer sensitivity 85%, specificity 74%) PE was excluded safely in 23.8% of patients but only by lowering the cut-off value of the Wells rule to In scenario 2 (Simplify-D-dimer sensitivity 87%, specificity 62%) PE was excluded safely in 12.4% of patients provided that the Wells-cut-off value was set at 0. (failure rate: 0.9%, 95% CI 0.2-2.6%) Conclusion Theoretically a diagnostic strategy using the Wells-CDR combined with a qualitative POC-D-dimer test can be used safely to exclude PE in primary care albeit with only moderate efficiency.