EPJ Web of Conferences (Jan 2017)

Discharge initiation by ICRF antenna in IShTAR

  • Tripský Matěj,
  • Wauters Tom,
  • D’Inca Rodolphe,
  • Crombé Kristel,
  • Jacquot Jonathan,
  • Ochoukov Roman,
  • Louche Fabrice,
  • Usoltceva Mariia,
  • Kostic Ana,
  • Lyssoivan Anatoli,
  • Noterdaeme Jean-Marie,
  • Van Schoor Michael

DOI
https://doi.org/10.1051/epjconf/201715703056
Journal volume & issue
Vol. 157
p. 03056

Abstract

Read online

IShTAR is a linear magnetized plasma test facility dedicated to the investigation of RF wave/plasma interaction. The IShTAR ICRF system consists of a single strap RF antenna. When using the antenna for plasma production without an external plasma source, it is shown that the plasma is either produced in front of the antenna strap or inside the antenna box depending on the antenna parameters. Here, we present experimental and numerical investigation of the plasma initiation parametric dependencies. Detailed pressure and RF power scans were performed in helium at f = 5.22 MHz and f = 42.06 MHz. The experiment shows the parameter ranges for which the plasma is produced in front of the strap, or inside the antenna box. These ranges are validated by simulations with the RFdinity model, and by theoretical predictions.