Perm Journal of Petroleum and Mining Engineering (Mar 2016)

About the productivity of shaft air heater located along the perimeter of pithead

  • Nikolai I. Alymenko,
  • Aleksandr V. Nikolaev,
  • Viktor A. Nikolaev,
  • Anton A. Kamenskikh

DOI
https://doi.org/10.15593/2224-9923/2016.18.10
Journal volume & issue
Vol. 15, no. 18
pp. 91 – 98

Abstract

Read online

In the existing shaft air heaters that heat the air for air suppliers in the cold season heater channel is used. Part of the air from heater goes to the channel, another one is sucked through pithead by general shaft pressure drawdown formed by main ventilation installation. Wherein, mix of two air flow leads to shaft heat regime violation that could break the pressurization of intertubular sealers. Moreover, heater channel design is associated with additional expenditures. Paper describes the air heater, located in the pithead. The location of a heater in one line along pithead perimeter is the key feature. In this case there is no need to design heater channel, thus, there is no problem with mix of cold and heated air flows. Air processing it the heater located on the perimeter of pithead and mix of cold and heated air flows in the supplier from the channel was modeled in the software Soldworks flow simulation. The comparative analysis of both types of heater proved efficiency of proposed design of installation, smooth propagation of heat field along the all cross-section of air supplier, decrease of consumption of electric power for air processing and installation operation by transformation negative natural common excavation traction to positive.

Keywords