Cogent Engineering (Jan 2019)
The effect of brine mass rate on circumferential and longitudinal stress in vertical type separator design
Abstract
The geothermal power plant is converting steam to electricity. The evaporation process in the evaporator produces wet steam (brine). The Brine has a high temperature and contains water, which is quite dominating. Therefore, a separator is needed to separate between ammonia-rich vapor that will flow into the turbine and ammonia-poor liquid, which will flow to the regenerator. In this case, the optimal separation uses a vertical separator. The design of vertical separator produces the specifications for brine mass flow rates 55.275 kg/s at circumferential stress 614.93 bar and brine mass flow rates 1.124 kg/s at longitudinal stresses of 1229.87 bar. The analysis result of brine mass flow rate on the lowest circumferential stress was 16.583 kg/s at 573.71 bar, and the highest was 181.372 kg/s at 628.94 bar, while the brine mass flow rate on the lowest longitudinal stress was 1.048 kg/s at 1,147.42 bar and the highest is 1.149 kg/s at 1,257.88 bar.
Keywords