Results in Engineering (Mar 2024)

Influence of microstructure and geometric dimension on metal magnetic memory testing

  • Huipeng Wang,
  • Zhiwei Xu,
  • Haihang Li,
  • Lihong Dong,
  • Haidou Wang,
  • Huizhong Liu

Journal volume & issue
Vol. 21
p. 101923

Abstract

Read online

Metal magnetic memory testing (MMMT) is a prominent NDT method for early damage diagnosis of ferromagnetic structures due to its significant advantages in stress concentration state evaluation. While it is still challengeable to apply the existing criteria from the laboratory to practical application, and some of the main reasons are the microstructure transformation and geometric dimensions for the ferromagnetic material itself. To explore the influence of microstructure and geometric dimension on MMMT, static tensile tests of specimens made of Optim 900QC steel with different microstructures and geometric dimensions have been carried out, and the MMMT signals of the specimens during the tests were collected and analyzed. It is found that the microstructure not only change the strength of the steel, but also affect the MMMT signal of the steel, and the bigger the grain is, the stronger the magnetic field is. Geometric dimension would also affect the MMMT signal, and thickness affects the MMMT signal the most, width less, and length the least. The results of the present work indicate that the microstructure and the geometric dimensions should be the same to fix the gap of damage determination criteria between the laboratory and the engineering application. When it is impossible to fabricate specimens with the same dimension with the engineering structure, set the same thickness would improve the accuracy of the criteria.