Scientific Reports (Sep 2024)

The study of plain CT combined with contrast-enhanced CT-based models in predicting malignancy of solitary solid pulmonary nodules

  • Wenjia Zhang,
  • Xiaonan Cui,
  • Jing Wang,
  • Sha Cui,
  • Jianghua Yang,
  • Junjie Meng,
  • Weijie Zhu,
  • Zhiqi Li,
  • Jinliang Niu

DOI
https://doi.org/10.1038/s41598-024-72592-9
Journal volume & issue
Vol. 14, no. 1
pp. 1 – 9

Abstract

Read online

Abstract To compare the diagnostic performance between plain CT-based model and plain plus contrast CT-based modelin the classification of malignancy for solitary solid pulmonary nodules. Between January 2012 and July 2021, 527 patients with pathologically confirmed solitary solid pulmonary nodules were collected at dual centers with similar CT examinations and scanning parameters. Before surgery, all patients underwent both plain and contrast-enhanced chest CT scans. Two clinical characteristics, fifteen plain CT characteristics, and four enhanced characteristics were used to develop two logistic regression models: model 1 (plain CT only) and model 2 (plain + contrast CT). The diagnostic performance of the two models was assessed separately in the development and external validation cohorts using the AUC. 392 patients from Center A were included in the training cohort (median size, 20.0 [IQR, 15.0–24.0] mm; mean age, 55.8 [SD, 9.9] years; male, 53.3%). 135 patients from Center B were included in the external validation cohort (median size, 20.0 [IQR, 16.0–24.0] mm; mean age, 56.4 [SD, 9.6] years; male, 51.9%). Preoperative patients with 201 malignant (adenocarcinoma, 148 [73.6%]; squamous cell carcinoma, 35 [17.4%]; large cell carcinoma,18 [9.0%]) and 326 benign (pulmonary hamartoma, 118 [36.2%]; sclerosing pneumocytoma, 35 [10.7%]; tuberculosis, 104 [31.9%]; inflammatory pseudonodule, 69 [21.2%]) solitary solid pulmonary nodules were gathered from two independent centers. The mean sensitivity, specificity, accuracy, PPV, NPV, and AUC (95%CI) of model 1 (Plain CT only) were 0.79, 0.78, 0.79, 0.67, 0.87, and 0.88 (95%CI, 0.82–0.93), the model 2 (Plain + Contrast CT) were 0.88, 0.91, 0.90, 0.84, 0.93, 0.93 (95%CI, 0.88–0.98) in external validation cohort, respectively. A logistic regression model based on plain and contrast-enhanced CT characteristics showed exceptional performance in the evaluation of malignancy for solitary solid lung nodules. Utilizing this contrast-enhanced CT model would provide recommendations concerning follow-up or surgical intervention for preoperative patients presenting with solid lung nodules.

Keywords