Sensors (Jun 2021)

Fabrication and Qualitative Analysis of an Optical Fibre EFPI-Based Temperature Sensor

  • Fintan McGuinness,
  • Aidan Cloonan,
  • Mohamed Oubaha,
  • Dinesh Babu Duraibabu,
  • M. Mahmood Ali,
  • Gerald Kilkelly,
  • Emma Tobin,
  • Gabriel Leen

DOI
https://doi.org/10.3390/s21134445
Journal volume & issue
Vol. 21, no. 13
p. 4445

Abstract

Read online

The following presents a comparison of an extrinsic Fabry–Perot interferometer (EFPI)-based temperature sensor, constructed using a novel diaphragm manufacturing technique, with a reference all-glass EFPI temperature sensor. The novel diaphragm was manufactured using polyvinyl alcohol (PVA). The novel sensor fabrication involved fusing a single-mode fibre (SMF) to a length of fused quartz capillary, which has an inner diameter of 132 μm and a 220 μm outer diameter. The capillary was subsequently polished until the distal face of the capillary extended approximately 60 μm beyond that of the single mode fibre. Upon completion of polishing, the assembly is immersed in a solution of PVA. Controlled extraction resulted in creation of a thin diaphragm while simultaneously applying a protective coating to the fusion point of the SMF and capillary. The EFPI sensor is subsequently sealed in a second fluid-filled capillary, thereby creating a novel temperature sensor structure. Both temperature sensors were placed in a thermogravimetric analyser and heated from an indicated 30 °C to 100 °C to qualitatively compare sensitivities. Initial results indicated that the novel manufacturing technique both expedited production and produces a more sensitive sensor when compared to an all-glass construction.

Keywords