Incineration plants using solid refused fuel (SRF) should control their air pollution materials to minimize environmental impact. This study evaluated the emission of polychlorinated dibenzo-p-dioxin/dibenzofurans (PCDD/DFs) congener patterns in seven commercial incineration plants in Korea using SRF and biomass SRF (bio-SRF). We examined the reduction rate differences of PCDD/DFs, depending on the air pollutant control device. All seven incineration plants sufficiently managed their dioxin emissions. However, both SRF and bio-SRF incineration plants showed active chlorination reactions and resulted in a large amount of highly chlorinated dioxins. The average dioxin concentration was 0.02 ng international toxic equivalency quantity (I-TEQ)/Sm3. Ratios of 1,2,3,4,6,7,8-HpCDF and 1,2,3,7,8-PeCDF were high in the waste heat boilers of both SRF and bio-SRF incineration plants. The octachlorinated dibenzofuran (OCDF) ratio was only high in the SRF incineration plants. Octachlorodibenzo-p-dioxin (OCDD) and OCDF exhibited high dioxin ratios. SRF incineration plants had a low ratio of OCDF to 1,2,3,4,6,7,8-HpCDF. In addition, the reduction rate of PCDD/DFs was substantially high after treatment with the air pollutant control device.