PLoS ONE (Jan 2017)

Texture analysis of acute myocardial infarction with CT: First experience study.

  • Ricarda Hinzpeter,
  • Matthias W Wagner,
  • Moritz C Wurnig,
  • Burkhardt Seifert,
  • Robert Manka,
  • Hatem Alkadhi

DOI
https://doi.org/10.1371/journal.pone.0186876
Journal volume & issue
Vol. 12, no. 11
p. e0186876

Abstract

Read online

To investigate the feasibility and accuracy of texture analysis to distinguish through objective and quantitative image information between healthy and infarcted myocardium with computed tomography (CT).Twenty patients (5 females; mean age 56±10years) with proven acute myocardial infarction (MI) and 20 patients (8 females; mean age 42±15years) with no cardiac abnormalities (hereafter termed controls) underwent contrast-enhanced cardiac CT. Short axis CT images of the left ventricle (LV) were reconstructed at the slice thicknesses 1mm, 2mm, and 5mm. Two independent, blinded readers segmented the LV in controls and patients. Texture analysis was performed yielding first-level features based on the histogram (variance, skewness, kurtosis, entropy), second-level features based on the gray-level co-occurrence matrix (GLCM) (contrast, correlation, energy and homogeneity), and third-level features based on the gray-level run-length matrix (GLRLM).Inter-and intrareader agreement was good to excellent for all histogram (intraclass correlation coefficient (ICC):0.70-0.93) and for all GLCM features (ICC:0.66-0.99), and was variable for the GLRLM features (ICC:-0.12-0.99). Univariate analysis showed significant differences between patients and controls for 2/4 histogram features, 3/4 GLCM and for 6/11 GLRLM features and all assessed slice thicknesses (all,p<0.05). In a multivariate logistic regression model, the single best variable from each level, determined by ROC analysis, was included stepwise. The best model included kurtosis (OR 0.08, 95%CI:0.01-0.65,P = 0.018) and short run high gray-level emphasis (SRHGE, OR 0.97, 95%CI:0.94-0.99,P = 0.007), with an area-under-the-curve (AUC) of 0.90 (95%CI:0.80-0.99). The best results for kurtosis and SRHGE (AUC = 0.78) were obtained at a 5mm slice thickness. A cut-off value of 14.4 for kurtosis+0.013*SRHGE predicted acute MI with a sensitivity of 95% (specificity 55%).Our study illustrates the feasibility of texture analysis for distinguishing healthy from acutely infarcted myocardium with cardiac CT using objective, quantitative features, with most reproducible and accurate results at a short axis slice thickness of 5mm.