Acta Amazonica (Mar 2017)
Refractometry as an alternative to the biuret method for measuring total serum proteins in Podocnemis expansa (Podocnemididae) and Phrynops geoffroanus (Chelidae)
Abstract
ABSTRACT Total serum protein is a significant indicator of health condition in animals. The aim of this study was to analyze the precision of the portable refractometer in determining the concentration of total serum proteins in Podocnemis expansa and Phrynops geoffroanus. A total of 26 animals were used. The blood samples were collected from the supraoccipital sinus and stored in tubes without anticoagulant. Total serum protein was determined using both the biuret reaction and refractometry. The total serum protein mean concentration (g dL-1) with biuret method and refractometry for P. expansa were 3.16 and 3.2; and for P. geoffroanus were 3.56 and 2.72, respectively. These results indicate that total serum protein values can be determined with precision in P. expansa and P. geoffroanus using a portable refractometer.
Keywords