Biomechanics (Apr 2023)

Reliability of a Pendulum Apparatus for the Execution of Plyometric Rebound Exercises and the Comparison of Their Biomechanical Parameters with Load-Matching Vertical Drop Jumps

  • Vassilios Panoutsakopoulos,
  • Iraklis A. Kollias

DOI
https://doi.org/10.3390/biomechanics3020018
Journal volume & issue
Vol. 3, no. 2
pp. 204 – 219

Abstract

Read online

The inability to control the body center of mass (BCM) initial conditions, when executing plyometric exercises, comprises a restrictive factor to accurately compare jumps executed vertically and horizontally. The purpose of the study was to present a methodological approach for the examination of BCM initial conditions during vertical drop jumps (VDJ) and plyometric rebound jumps performed with a pendulum swing (HPRJ). A system consisting of two force plates was used for the evaluation of VDJ. A bifilar pendulum, equipped with a goniometer and accelerometer, was constructed for the evaluation of the HPRJ. Kinematic parameters from both jump modalities were obtained by means of videography (100 Hz). Thirty-eight physically active young males executed VDJ and HPRJ with identical BCM kinetic energy at the instant of impact (KEI). Results revealed that participants produced higher power and lower force outputs at HPRJ (p < 0.01). The rate of force development was larger in VDJ, while hip movement was less in HPRJ. The use of the presented methodology provided the means to reliably determine the exact BCM release height during the execution of the examined jumps. This provided an accurate determination of the amount of KEI, being the main parameter of calculating load during plyometric exercise.

Keywords