Materials (Nov 2022)

On the Use of NaOH Solution to Simulate the Crevice Conditions of a Nuclear Steam Generator

  • Do-Haeng Hur,
  • Geun-Dong Song,
  • Jeoh Han,
  • Soon-Hyeok Jeon

DOI
https://doi.org/10.3390/ma15238471
Journal volume & issue
Vol. 15, no. 23
p. 8471

Abstract

Read online

The corrosion behavior and integrity of steam generator (SG) tube materials have frequently been tested in solutions containing sodium hydroxide (NaOH), assuming that NaOH is a typical contaminant concentrated in the crevices of SGs in a pressurized water reactor. The purpose of this study was to investigate the adequacy of using concentrated NaOH solutions to simulate the crevice environments of SGs. The dissolution behavior of magnetite deposit flakes formed in an operating SG was tested in a 0.4 wt.% NaOH solution at 300 °C, and the thermodynamic stability of magnetite was investigated using the potential-pH diagram for an iron–water system. The magnetite deposits were rapidly dissolved in the test solution, which was supported by the fact that magnetite is thermodynamically unstable under the test condition to dissolve to dihypoferrite ions (HFeO2−). These results indicate that research data obtained from concentrated NaOH solutions are not appropriate to apply to the crevice environments of SGs.

Keywords