Journal of Combustion (Jan 2012)

Extending Lean Operating Limit and Reducing Emissions of Methane Spark-Ignited Engines Using a Microwave-Assisted Spark Plug

  • Vi H. Rapp,
  • Anthony DeFilippo,
  • Samveg Saxena,
  • Jyh-Yuan Chen,
  • Robert W. Dibble,
  • Atsushi Nishiyama,
  • Ahsa Moon,
  • Yuji Ikeda

DOI
https://doi.org/10.1155/2012/927081
Journal volume & issue
Vol. 2012

Abstract

Read online

A microwave-assisted spark plug was used to extend the lean operating limit (lean limit) and reduce emissions of an engine burning methane-air. In-cylinder pressure data were collected at normalized air-fuel ratios of λ=1.46, λ=1.51, λ=1.57, λ=1.68, and λ=1.75. For each λ, microwave energy (power supplied to the magnetron per engine cycle) was varied from 0 mJ (spark discharge alone) to 1600 mJ. At lean conditions, the results showed adding microwave energy to a standard spark plug discharge increased the number of complete combustion cycles, improving engine stability as compared to spark-only operation. Addition of microwave energy also increased the indicated thermal efficiency by 4% at λ=1.68. At λ=1.75, the spark discharge alone was unable to consistently ignite the air-fuel mixture, resulting in frequent misfires. Although microwave energy produced more consistent ignition than spark discharge alone at λ=1.75, 59% of the cycles only partially burned. Overall, the microwave-assisted spark plug increased engine performance under lean operating conditions (λ=1.68) but did not affect operation at conditions closer to stoichiometric.