Diagnostics (Feb 2024)
Can the ADC Value Be Used as an Imaging “Biopsy” in Endometrial Cancer?
Abstract
Background: The tumor histological grade is closely related to the prognosis of patients with endometrial cancer (EC). Multiparametric MRI, including diffusion-weighted imaging (DWI), provides information about the cellular density that may be useful to differentiate between benign and malignant uterine lesions. However, correlations between apparent diffusion coefficient (ADC) values and histopathological grading in endometrial cancer remain controversial. Material and methods: We retrospectively evaluated 92 patients with endometrial cancers, including both endometrioid adenocarcinomas (64) and non-endometrioid adenocarcinomas (28). All patients underwent DWI procedures, and mean ADC values were calculated in a region of interest. These values were then correlated with the tumor grading offered by the histopathological examination, which was considered the gold standard. In this way, the patients were divided into three groups (G1, G2, and G3). The ADC values were then compared to the results offered by the biopsy to see if the DWI sequence and ADC map could replace this procedure. We also compared the mean ADC values to the myometrial invasion (50%) and lymphovascular space invasion. Results: We have divided the ADC values into three categories corresponding to three grades: >0.850 × 10−3 mm2/s (ADC1), 0.730–0.849 × 10−3 mm2/s (ADC2) and −3 mm2/s (ADC3). The diagnostic accuracy of the ADC value was 85.71% for ADC1, 75.76% for ADC2, and 91.66% for ADC3. In 77 cases out of 92, the category in which they were placed using the ADC value corresponded to the result offered by the histopathological exam with an accuracy of 83.69%. For only 56.52% of patients, the biopsy result included the grading system. For each grading category, the mean ADC value showed better results than the biopsy; for G1 patients, the mean ADC value had an accuracy of 85.71% compared to 66.66% in the biopsy, G2 had 75.76% compared to 68.42%, and G3 had 91.66 compared to 75%. For both deep myometrial invasion and lymphovascular space invasion, there is a close, inversely proportional correlation with the mean ADC value. Conclusions: Mean endometrial tumor ADC on MR-DWI is inversely related to the histological grade, deep myometrial invasion and lymphovascular space invasion. Using this method, the patients could be better divided into risk categories for personalized treatment.
Keywords