Diagnostics (Mar 2024)
A Rapid On-Line Evaluation (ROLE) Protocol in the Diagnostic Performance Improvement in Endoscopic Ultrasound-Guided Tissue Acquisition for Solid Pancreatic Lesions
Abstract
We assessed the rapid on-line evaluation (ROLE) protocol as a modification to the conventional rapid on-site evaluation (ROSE) in the diagnostic performance improvement in endoscopic ultrasound-guided tissue acquisition (EUS-TA) for solid pancreatic lesions. This single-center, retrospective study involved consecutive patients with solid pancreatic lesions undergoing EUS-TA at Peking University First Hospital between October 2017 and March 2021. Among 137 patients enrolled, 75 were in the ROLE group and 62 were in the non-ROSE group. The diagnostic yield (97.3% vs. 85.5%, p = 0.023), accuracy (94.7% vs. 82.3%, p = 0.027), and sensitivity (95.7% vs. 81.1%, p = 0.011) were significantly higher in the ROLE group compared to the non-ROSE group. However, specificity, positive predictive value, negative predictive value, and area under the curve (AUC) showed no significant differences (all p-values > 0.05). Additionally, there was a noteworthy reduction in the number of needle passes required in the ROLE group compared to the non-ROSE group (two vs. three, p 0.001). In a subgroup analysis, fine needle biopsy (FNB) combined with ROLE demonstrated superior diagnostic accuracy compared to FNB with non-ROSE (100% vs. 93.1%, p = 0.025). Compared with the non-ROSE protocol, the ROLE protocol might improve the diagnostic performance of EUS-TA for solid pancreatic lesions, and potentially reduce the number of needle passes requirement.
Keywords