Case Studies in Construction Materials (Dec 2023)

Effect of mixing ratio on fire resistance of cement mortar with polypropylene fiber and polymer

  • KiSoo Jeon,
  • Chansoo Jeon,
  • Wonyoung Choi

Journal volume & issue
Vol. 19
p. e02503

Abstract

Read online

Polymer cement mortar is commonly used as a repair material for reinforced-concrete (RC) structures owing to its high resistance to degradation factors, except for high-temperature environments. Here, the fire resistance of fiber-mixed polymer cement mortar was evaluated according to the polymer content and polypropylene (PP) fiber length and content to identify the optimal mix for ensuring adequate fire resistance of polymer cement mortar. Furthermore, a 3-h fire resistance test was conducted on specimens with different moisture content. The probability of spalling increased with increasing moisture content and polymer content and decreased with increasing length and content of PP fibers.

Keywords