Известия высших учебных заведений: Проблемы энергетики (Dec 2017)

FEATURES OF MONITORING PARTIAL DISCHARGE IN THE STATOR WINDING INSULATION OF TURBINE GENERATORS, INCLUDED IN THE NETWORK

  • B. A. Ba,
  • A. E. Usachev,
  • A. Kubarev,
  • S. M. Margulis

DOI
https://doi.org/10.30724/1998-9903-2017-19-3-4-80-88
Journal volume & issue
Vol. 19, no. 3-4
pp. 80 – 88

Abstract

Read online

In this paper reports the results of studies of the surveillance of partial discharge (PD) in the stator the turbine generator (TG) TVF-60-2 when its work on the network. Shown that, for a correct interpretation of the measurement results PD in TG, it is necessary to know winding diagram and the order of their location in the stator slots; circuit crossing them in the end-winding and the stress distribution at the bars in the slot and end-winding part of the TG. Consequently, series-connected stator bars potentially different relative to the ground, the conditions of occurrence of PD in each bar in the slot and end-winding part are substantially different and the phase of occurrence of PD becomes ambiguous parameter.