Micromachines (Apr 2012)

Time of Flight Sensor with a Flow Parallel Wire

  • Werner Karl Schomburg,
  • Christof Gerhardy

DOI
https://doi.org/10.3390/mi3020325
Journal volume & issue
Vol. 3, no. 2
pp. 325 – 330

Abstract

Read online

A time of flight sensor has been equipped with a sensing wire parallel to the flow direction (flow parallel wire, FPW). A heat pulse is generated with a coil in the flow channel. The FPW has a center tap allowing its upstream and downstream parts to join in a half bridge. When a heat pulse passes the FPW, a large output peak is generated. The time between heat pulse generation and recording the peak maximum is only marginally affected by the properties of the fluid. With a combination of two FPWs, a measuring range of approximately 0.01–0.5 m/s can be achieved.

Keywords