Sensors (Feb 2023)

Comparison between Two Time Synchronization and Data Alignment Methods for Multi-Channel Wearable Biosensor Systems Using BLE Protocol

  • He Wang,
  • Jianan Li,
  • Benjamin E. McDonald,
  • Todd R. Farrell,
  • Xinming Huang,
  • Edward A. Clancy

DOI
https://doi.org/10.3390/s23052465
Journal volume & issue
Vol. 23, no. 5
p. 2465

Abstract

Read online

Wireless wearable sensor systems for biomedical signal acquisition have developed rapidly in recent years. Multiple sensors are often deployed for monitoring common bioelectric signals, such as EEG (electroencephalogram), ECG (electrocardiogram), and EMG (electromyogram). Compared with ZigBee and low-power Wi-Fi, Bluetooth Low Energy (BLE) can be a more suitable wireless protocol for such systems. However, current time synchronization methods for BLE multi-channel systems, via either BLE beacon transmissions or additional hardware, cannot satisfy the requirements of high throughput with low latency, transferability between commercial devices, and low energy consumption. We developed a time synchronization and simple data alignment (SDA) algorithm, which was implemented in the BLE application layer without the need for additional hardware. We further developed a linear interpolation data alignment (LIDA) algorithm to improve upon SDA. We tested our algorithms using sinusoidal input signals at different frequencies (10 to 210 Hz in increments of 20 Hz—frequencies spanning much of the relevant range of EEG, ECG, and EMG signals) on Texas Instruments (TI) CC26XX family devices, with two peripheral nodes communicating with one central node. The analysis was performed offline. The lowest average (±standard deviation) absolute time alignment error between the two peripheral nodes achieved by the SDA algorithm was 384.3 ± 386.5 μs, while that of the LIDA algorithm was 189.9 ± 204.7 μs. For all sinusoidal frequencies tested, the performance of LIDA was always statistically better than that of SDA. These average alignment errors were quite low—well below one sample period for commonly acquired bioelectric signals.

Keywords