PeerJ (May 2020)

Discordance of vancomycin minimum inhibitory concentration for methicillin-resistant Staphylococcus aureus at 2 μg/mL between Vitek II, E-test, and Broth Microdilution

  • Chien-Feng Kuo,
  • Chon Fu Lio,
  • Hsiang-Ting Chen,
  • Yu-Ting Tina Wang,
  • Kevin Sheng-Kai Ma,
  • Yi Ting Chou,
  • Fu-Chieh Chang,
  • Shin-Yi Tsai

DOI
https://doi.org/10.7717/peerj.8963
Journal volume & issue
Vol. 8
p. e8963

Abstract

Read online Read online

Background Vancomycin, the first line antibiotic for methicillin-resistant Staphylococcus aureus (MRSA) bacteremia, is often administered inappropriately when MIC is greater than 2 µg/mL, including ‘susceptible’ strains. This study assessed the discordance of vancomycin minimum inhibitory concentration (MIC) for methicillin-resistant Staphylococcus aureus (MRSA). Methods In total, 229 MRSA isolates from blood cultures collected between 2009 and 2015 at a tertiary hospital in Taiwan were examined. The MICs of vancomycin were measured using Vitek 2, E-test, and standard broth microdilution at the level of 2 µg/mL. Results The geometric mean of the MICs of hospital-acquired MRSA was higher than that of community-acquired MRSA (P < 0.001), with the exact agreement rates (with broth microdilution) at 2 µg/mL being 53.6% in Vitek 2 and 86.7% in E-test. Overall, E-test (98.1%) had more categorical accordance than did Vitek 2 (94.0%; P = 0.026). Vitek 2 had a tendency to overestimate MRSA in high-MIC isolates, whereas E-test inclined underestimation in low-MIC isolates. Surprisingly, the discordance rates of MRSA vancomycin MICs were higher in hospital-acquired isolates (13.3%–17.0%) than in community-acquired isolates (6.2%–7.0%). Conclusion The Infectious Diseases Society of America recommends the use of alternative antimicrobial agents when vancomycin MIC is ≥ 2 µg/mL; in this study, only 53.6% of the isolates tested using Vitek 2 showed a high MIC in the broth microdilution method. Accurate identification of the resistance profile is a key component of antimicrobial stewardship programs. Therefore, to reduce inappropriate antibiotic use and mitigate the emergence of resistant strains, we recommend using complementary tests such as E-test or Broth microdilution to verify the MIC before administering second-line antibiotics. Strengths (1) We compared the categorical agreement between different methods measuring MRSA MICs level. (2) Physicians should incorporate this information and consider a complementary test to verify the appropriateness of the decision of shifting vancomycin to second-line antibiotic treatment to improve patients’ prognosis. (3) MRSA-vancomycin MICs at a cutoff of 2 µg/mL obtained using Vitek II exhibited a higher sensitivity level and negative predictive value than those obtained using E-test in the prediction of categorical agreement with standard broth microdilution. Limitation (1) Our research was based on a single hospital-based study. (2) The MRSA strains in this study were stored for more than 12 months after isolation. (3) We did not collect information on clinical prognosis.

Keywords