Frontiers in Oncology (Aug 2024)

A novel x-Ray and γ-Ray combination strategy for radiotherapy after breast-conserving surgery in patients with right breast cancer

  • Kunpeng Zhang,
  • Ruixin He,
  • Fenwen Tang,
  • Luping Zhou,
  • Xiaozhi Zhang,
  • Jinsheng Li,
  • Zhiwei Wei,
  • Yi Li

DOI
https://doi.org/10.3389/fonc.2024.1397273
Journal volume & issue
Vol. 14

Abstract

Read online

Background and purposeRadiotherapy is a primary therapeutic approach for breast cancer following breast-conserving surgery. The TaiChiB dual-modality radiotherapy system combining X-ray and focused γ-ray, offers a new approach to reduce the radiation dose of organs at risk (OARs) and has the potential to mitigate the adverse effects of radiotherapy. Currently, there are few studies on the dosimetric characteristics of the TaiChiB dual-modality system for actual treatment plans for specific diseases. The purpose of this work is to study the dosimetric advantages of dual-modal systems for right breast patients after breast-conserving surgery.Material and methodsTreatment plans for 20 patients with right breast cancer were generated for a linear accelerator (LINAC) based system and the TaiChiB dual-modality system, respectively. Volumetric modulated arc therapy plans with simultaneous integrated boost (VMAT-SIB) were made for the LINAC. Focused γ-ray was used to deliver the boost dose with the dual-modality system. The dosimetric parameters of the target and OARs were evaluated and compared between the treatment plans generated for the two systems.ResultsThe TaiChiB dual-modality plans exhibit a higher conformal index (CI) and lower gradient index (GI) for the PGTV and PTV compared with the LINAC-based VMAT-SIB plans. Compared to VMAT-SIB plans, the PTV Dmax, PTV Dmean, PTV V110, PGTV Dmax, and PGTV Dmean of the TaiChiB dual-modality plans are significantly lower. Meanwhile, the dose to OARs, such as the Dmean of the heart, the V5 of liver, the Dmean of ipsilateral lung, the V30 of ipsilateral lung, the V20 of ipsilateral lung, the V5 of ipsilateral lung, the Dmean of contralateral lung, Dmax of contralateral breast and the Dmean of contralateral breast are significantly reduced.ConclusionsOur study demonstrates the dosimetric advantages of the novel TaiChiB dual-modality radiotherapy system for the treatment of right-sided breast cancer. Overall, for the TaiChiB dual-modality radiotherapy system, the radiation dose outside the target region decreases rapidly, thereby minimizing radiation exposure to neighboring organs and ensuring the conformity of the target area. Our research confirms the potential of the TaiChiB dual-modality system for future radiotherapy.

Keywords