Acta Veterinaria Scandinavica (Sep 2024)

Environmental bacterial load during surgical and ultrasound procedures in a Swedish small animal hospital

  • Todd Alsing-Johansson,
  • Karin Bergström,
  • Susanna Sternberg-Lewerin,
  • Anna Bergh,
  • Emma Östlund,
  • Johanna Penell

DOI
https://doi.org/10.1186/s13028-024-00768-4
Journal volume & issue
Vol. 66, no. 1
pp. 1 – 13

Abstract

Read online

Abstract Background Environmental bacteria in animal healthcare facilities may constitute a risk for healthcare-associated infections (HAI). Knowledge of the bacterial microflora composition and factors influencing the environmental bacterial load can support tailored interventions to lower the risk for HAI. The aims of this study were to: (1) quantify and identify environmental bacteria in one operating room (OR) and one ultrasound room (UR) in a small animal hospital, (2) compare the bacterial load to threshold values suggested for use in human healthcare facilities, (3) characterise the genetic relationship between selected bacterial species to assess clonal dissemination, and (4) investigate factors associated with bacterial load during surgery. Settle plates were used for passive air sampling and dip slides for surface sampling. Bacteria were identified by Matrix Assisted Laser Desorption—Time Of Flight. Antimicrobial susceptibility was determined by broth microdilution. Single nucleotide polymorphism-analysis was performed to identify genetically related isolates. Linear regression was performed to analyse associations between observed explanatory factors and bacterial load. Results The bacterial load on settle plates and dip slides were low both in the OR and the UR, most of the samples were below threshold values suggested for use in human healthcare facilities. All settle plates sampled during surgery were below the threshold values suggested for use in human clean surgical procedures. Staphylococcus spp. and Micrococcus spp. were the dominating species. There was no indication of clonal relationship among the sequenced isolates. Bacteria carrying genes conveying resistance to disinfectants were revealed. Air change and compliance with hygiene routines were sufficient in the OR. No other factors possibly associated with the bacterial load were identified. Conclusions This study presents a generally low bacterial load in the studied OR and UR, indicating a low risk of transmission of infectious agents from the clinical environment. The results show that it is possible to achieve bacterial loads below threshold values suggested for use in human healthcare facilities in ORs in small animal hospitals and thus posing a reduced risk of HAI. Bacteria carrying genes conveying resistance to disinfectants indicates that resistant bacteria can persist in the clinical environment, with increased risk for HAI.

Keywords