Abstract

Read online

This research was conducted to investigate a suitable location for the OTEC (Ocean Thermal Energy Conversion) pilot plant in North Bali. The investigation was done by calculating the theoretical potential of electric power output using the method of Uehara and Ikegami (1990) for closed cycle OTEC. OTEC power plants require a temperature difference between surface and bottom water layers at least 20°C. Temperature data were obtained from the HYCOM temperature model for a period of 9 years (2008 - 2017) at 4 points which were verified with field data taken in 2017 using KR Geomarin III. The results of field measurements show that the sea surface temperature (SST) in the study area ranges from 28 to 31°C while at depth of 800 m 5.75°C. ∆T values range from 22 to 25°C. Verification of modelling temperature and measurement temperature shows that the modeling results resemble the temperature of North Bali Waters. Analyses results for the four points showed that B-11, located in the Tedjakula area, has the largest electrical power output (71,109 MW). Thus, point B-11 is the best location for development of OTEC pilot plant in North Bali Waters.

Keywords