Water (Aug 2019)

Protecting a Pumping Pipeline System from Low Pressure Transients by Using Air Pockets: A Case Study

  • Rafael Bernardo Carmona-Paredes,
  • Oscar Pozos-Estrada,
  • Libia Georgina Carmona-Paredes,
  • Alejandro Sánchez-Huerta,
  • Eduardo Antonio Rodal-Canales,
  • Germán Jorge Carmona-Paredes

DOI
https://doi.org/10.3390/w11091786
Journal volume & issue
Vol. 11, no. 9
p. 1786

Abstract

Read online

This paper presents a case study of an existing water pipeline with five pumping stations each equipped with five pumps. In order to study the pipeline behavior prior to putting the system into operation, several transient simulations for different scenarios were developed. Results revealed that the most serious situation occurred when a simultaneous failure of the five pumps occur at each station caused by power cut, producing negative pressure waves because the system for control of hydraulic transients of the pipeline was insufficient to suppress downsurge pressures, due to the moment of inertia of all the pumps being erroneously considered during the design stage. The necessity to start supplying water to the population led to attempt an unconventional form of protecting the line against low pressures. The solution was to operate two of the five pumps per plant, and permit air to enter through combination air valves located along the pipeline. Air entrained formed pockets that remained stationary at the air valves locations, acting as air cushions that absorbed the energy of transient pressure waves. Computational simulations were conducted considering that two pumps are in operation at each plant and suddenly these fail simultaneously caused by power failure. The program was verified by comparing the calculated results with those registered during field pressure measurements. It was noticed that the surge modelling results are in good agreement with the measured data; furthermore, these show the air pockets in combination with existing devices for transient control protect the system adequately, avoiding potential damage to the pipeline.

Keywords