Türk Oftalmoloji Dergisi (Apr 2019)

Repeatability and Agreement of Macular Thickness Measurements Obtained with Two Different Scan Modes of the Optovue RTVue Optical Coherence Tomography Device

  • Mehmet Kola,
  • Mehmet Önal,
  • Adem Türk,
  • Hidayet Erdöl

DOI
https://doi.org/10.4274/tjo.galenos.2018.88972
Journal volume & issue
Vol. 49, no. 2
pp. 78 – 83

Abstract

Read online

Objectives:To evaluate the repeatability and agreement of macular thickness measurements obtained with E-MM5 and MM6, two different scan modes, on the Optovue RTVue optic coherence tomography (OCT) device.Materials and Methods:Three consecutive macular thickness measurements in 30 healthy volunteers were taken using the OCT device E-MM5 and MM6 scan modes. The repeatability and agreement of these measurements obtained from the two scan modes and divided into nine anatomical regions based on early treatment diabetic retinopathy study were subjected to statistical analysis.Results:The mean age of the participants was 29.7±6.39 years. Intraclass correlation (all ICC values ≥0.86) and coefficient of variation (all coefficient of variation values ≤2%) analyses of consecutive OCT measurements in the nine regions of the macula obtained in both E-MM5 and MM6 scan modes gave high repeatability rates. Mean macular thickness values in the foveal region were 243.76±21.79 μm in E-MM5 mode and 247.04±19.83 μm in MM6 mode (p=0.543). Values for measurements obtained in E-MM5 and MM6 scan modes in parafoveal macular regions were also statistically similar (p>0.05 for all). However, a statistically significant difference was observed between the two modes in perifoveal macular measurements, except in the superior region.Conclusion:The Optovue RTVue OCT device gives highly repeatable measurement results for macular thicknesses in both E-MM5 and MM6 scan modes. However, it should be considered that measurements performed in E-MM5 and MM6 modes give different results in perifoveal regions.

Keywords