E3S Web of Conferences (Jan 2020)
Design and monitoring of energy-active facade module
Abstract
Testing of two facade modules under outdoor climatic conditions of Central Europe has been performed for more than two years. The paper analyses the results of long-term monitoring and shows potential benefits of prismatic glazing and photovoltaic-thermal (PVT) collectors integrated into one component. The prismatic glazing reflects beam radiation during summer period and transmits it during the winter period. During summer month solar irradiation transmitted through the prismatic glazing can be about 44 % lower compared to conventional triple glazing. Glazed PVT collector generates heat and electricity simultaneously. PVT collector integrated in the façade module can achieve solar yield during summer 58 kWh/m2.month in heat and 6,3 kWh/m2.month in electricity.