European Radiology Experimental (May 2021)

Implementation of a sagittal T2-weighted DIXON turbo spin-echo sequence may shorten MRI acquisitions in the emergency setting of suspected spinal bleeding

  • Nico Sollmann,
  • Charlotte Rüther,
  • Simon Schön,
  • Claus Zimmer,
  • Thomas Baum,
  • Jan S. Kirschke

DOI
https://doi.org/10.1186/s41747-021-00213-5
Journal volume & issue
Vol. 5, no. 1
pp. 1 – 11

Abstract

Read online

Abstract Background Magnetic resonance imaging (MRI) is the modality of choice for evaluating soft tissue damage along the spine in the emergency setting, yet access and fast protocol availability are limited. We assessed the performance of a sagittal T2-weighted DIXON turbo spin-echo sequence and investigated whether additional standard sagittal T1-weighted sequences are necessary in suspected spinal fluid collections/bleedings. Methods Seventy-four patients aged 62.9 ± 19.3 years (mean ± standard deviation) with MRI including a sagittal T2-weighted DIXON sequence and a T1-weighted sequence were retrospectively included. Thirty-four patients (45.9%) showed a spinal fluid collection/bleeding. Two layouts (layout 1: fat-only and water-only and in-phase images of the DIXON sequence and T1-weighted images; layout 2: fat-only and water-only and in-phase images of the DIXON sequence) were evaluated by three readers (R1, R2, and R3) concerning presence of spinal fluid collections/bleedings and diagnostic confidence from 1 (very low confidence) to 5 (very high confidence). χ 2 and κ statistics were used. Results There was no difference in detecting spinal fluid collections/bleedings between the layouts (R1 and R2 detected all, R3 missed one spinal fluid collection/bleeding in the same patient in both layouts). Confidence was high (layout 1, R1 4.26 ± 0.81, R2 4.28 ± 0.81, R3 4.32 ± 0.79; layout 2, R1 3.93 ± 0.70, R2 4.09 ± 0.86, R3 3.97 ± 0.73), with higher inter-reader agreement for layout 1 (κ 0.691–0.780) than for layout 2 (κ 0.441–0.674). Conclusions A sagittal T2-weighted DIXON sequence provides diagnostic performance similar to a protocol including standard T1-weighted sequences.

Keywords