EPJ Web of Conferences (Jan 2016)

Comparison of Long Term Tropospheric Ozone Trends Measured by Lidar and ECC Ozonesondes from 1991 to 2010 in Southern France

  • Ancellet G.,
  • Gaudel A.,
  • Godin-Beekmann S.

DOI
https://doi.org/10.1051/epjconf/201611920002
Journal volume & issue
Vol. 119
p. 20002

Abstract

Read online

ECC (Electrochemical Concentration Cell) ozonesondes and UV DIAL (Differential Absorption Lidar) measurements have been carried out simultaneously at OHP (Observatoire de Haute Provence, 44°N, 6.7°E, 690 m) since 1991. A unique long-term trend assessment by two different instruments operated routinely at the same location is possible. Air mass trajectories have been calculated for all the ozone observations available at OHP. The bias between the seasonal mean calculated with lidar and ECC ozone vertical profiles for 4 timeperiods of 5 years is 0.6 ppbv in the free troposphere (4-8 km). Larger differences (> 10 ppbv) are explained by the need for clear sky conditions during lidar observations. The measurements of both instruments have been combined to decrease the impact of short-term atmospheric variability on the trend estimate.