Abstract

Read online

ABSTRACT Widely available and reliable testing for SARS-CoV-2 is essential for the public health response to the COVID-19 pandemic. We estimated the diagnostic performance of reverse transcription PCR (RT-PCR) performed on saliva and the SD Biosensor STANDARD Q antigen test performed on nasopharyngeal swab compared to the reference standard, nasopharyngeal swab (NP) RT-PCR. We enrolled participants living and/or seeking care in health facilities in North Lima, Peru from November 2020 to January 2021. Consenting participants underwent same-day RT-PCR on both saliva and nasopharyngeal swab specimens, antigen testing on a nasopharyngeal swab specimen, pulse oximetry, and standardized symptom assessment. We calculated sensitivity, specificity, and predictive values for the nasopharyngeal antigen and saliva RT-PCR compared to nasopharyngeal RT-PCR. Of 896 participants analyzed, 567 (63.3%) had acute signs/symptoms of COVID-19. The overall sensitivity and specificity of saliva RT-PCR were 85.8% and 98.1%, respectively. Among participants with and without acute signs/symptoms of COVID-19, saliva sensitivity was 87.3% and 37.5%, respectively. Saliva sensitivity was 97.4% and 56.0% among participants with cycle threshold (CT) values of ≤30 and >30 on nasopharyngeal RT-PCR, respectively. The overall sensitivity and specificity of nasopharyngeal antigen were 73.2% and 99.4%, respectively. The sensitivity of the nasopharyngeal antigen test was 75.1% and 12.5% among participants with and without acute signs/symptoms of COVID-19, and 91.2% and 26.7% among participants with CT values of ≤30 and >30 on nasopharyngeal RT-PCR, respectively. Saliva RT-PCR achieved the WHO-recommended threshold of >80% for sensitivity for the detection of SARS-CoV-2, while the SD Biosensor nasopharyngeal antigen test did not. IMPORTANCE In this diagnostic validation study of 896 participants in Peru, saliva reverse transcription PCR (RT-PCR) had >80% sensitivity for the detection of SARS-CoV-2 among all-comers and symptomatic individuals, while the SD Biosensor STANDARD Q antigen test performed on nasopharyngeal swab had 80% sensitivity.

Keywords