Sensors (Apr 2019)

On-Line Monitoring of Pipe Wall Thinning by a High Temperature Ultrasonic Waveguide System at the Flow Accelerated Corrosion Proof Facility

  • Se-beom Oh,
  • Yong-moo Cheong,
  • Dong-jin Kim,
  • Kyung-mo Kim

DOI
https://doi.org/10.3390/s19081762
Journal volume & issue
Vol. 19, no. 8
p. 1762

Abstract

Read online

Pipe wall thinning and leakage due to flow accelerated corrosion (FAC) are important safety concerns for nuclear power plants. A shear horizontal ultrasonic pitch/catch technique was developed for the accurate monitoring of the pipe wall-thickness. A solid couplant should be used to ensure high quality ultrasonic signals for a long operation time at an elevated temperature. We developed a high temperature ultrasonic thickness monitoring method using a pair of shear horizontal transducers and waveguide strips. A computer program for on-line monitoring of the pipe thickness at high temperature was also developed. Both a conventional buffer rod pulse-echo type and a developed shear horizontal ultrasonic waveguide type for a high temperature thickness monitoring system were successfully installed to test a section of the FAC proof test facility. The overall measurement error was estimated as ±15 μm during a cycle ranging from room temperature to 150 °C. The developed waveguide system was stable for about 3300 h and sensitive to changes in the internal flow velocity. This system can be used for high temperature thickness monitoring in all industries as well as nuclear power plants.

Keywords