Abstract

Read online Read online

ABSTRACT For drip irrigation design and management, it is necessary to know the relation between flow and pressure acting on emitters. In the case of subsurface drip irrigation, the backpressure phenomenon may change the hydraulic characteristics of emitters. Thus, this study aimed at determining such relationship between flow and pressure of different driplines in surface and subsurface conditions; aiming to find possible differences in hydraulic behavior. We tested four emitter types; two pressure compensating (D5000 and Hydro PCND) and two non-pressure compensating (TalDrip and Jardiline). Emitter flow rates were attained in atmospheric conditions and submerged in water, in which submergence levels represented backpressure. Assays were performed using inlet pressures of 80, 100, 120, and 150 kPa for the Hydro PCND dripline and 25, 50, 100, and 150 kPa for the other ones; the backpressures were of 0.49, 1.47, 2.45, 4.41 and 6.37 kPa with four replications. The emitters had their proportionality constants and discharge exponents changed in submerged applications, representing backpressure effect. Non-pressure compensating emitters had their discharge exponent decreased, while in pressure compensating ones, it was increased. Backpressure reduced emitter flow rates at all evaluated pressures.