New Journal of Physics (Jan 2020)

Quantum magnetometry using two-stroke thermal machines

  • Sourav Bhattacharjee,
  • Utso Bhattacharya,
  • Wolfgang Niedenzu,
  • Victor Mukherjee,
  • Amit Dutta

DOI
https://doi.org/10.1088/1367-2630/ab61d6
Journal volume & issue
Vol. 22, no. 1
p. 013024

Abstract

Read online

The precise estimation of small parameters is a challenging problem in quantum metrology. Here, we introduce a protocol for accurately measuring weak magnetic fields using a two-level magnetometer, which is coupled to two (hot and cold) thermal baths and operated as a two-stroke quantum thermal machine. Its working substance consists of a two-level system (TLS), generated by an unknown weak magnetic field acting on a qubit, and a second TLS arising due to the application of a known strong and tunable field on another qubit. Depending on this field, the machine may either act as an engine or a refrigerator. Under feasible conditions, determining this transition point allows to reduce the relative error of the measurement of the weak unknown magnetic field by the ratio of the temperatures of the colder bath to the hotter bath.

Keywords