JMIR mHealth and uHealth (Jan 2021)
Physical Activity Monitoring Using a Fitbit Device in Ischemic Stroke Patients: Prospective Cohort Feasibility Study
Abstract
BackgroundContinuous tracking of ambulatory activity in real-world settings using step activity monitors has many potential uses. However, feasibility, accuracy, and correlation with performance measures in stroke patients have not been well-established. ObjectiveThe primary study objective was to determine adherence with wearing a consumer-grade step activity monitor, the Fitbit Charge HR, in home-going ischemic stroke patients during the first 90 days after hospital discharge. Secondary objectives were to (1) determine accuracy of step counts of the Fitbit Charge HR compared with a manual tally; (2) calculate correlations between the Fitbit step counts and the mobility performance scores at discharge and 30 days after stroke; (3) determine variability and change in weekly step counts over 90 days; and (4) evaluate patient experience with using the Fitbit Charge HR poststroke. MethodsA total of 15 participants with recent mild ischemic stroke wore a Fitbit Charge HR for 90 days after discharge and completed 3 mobility performance tests from the National Institutes of Health Toolbox at discharge and Day 30: (1) Standing Balance Test, (2) 2-Minute Walk Endurance Test, and (3) 4-Meter Walk Gait Speed Test. Accuracy of step activity monitors was assessed by calculating differences in steps recorded on the step activity monitor and a manual tally during 2-minute walk tests. ResultsParticipants had a mean age of 54 years and a median modified Rankin scale score of 1. Mean daily adherence with step activity monitor use was 83.6%. Mean daily step count in the first week after discharge was 4376. Daily step counts increased slightly during the first 30 days after discharge (average increase of 52.5 steps/day; 95% CI 32.2-71.8) and remained stable during the 30-90 day period after discharge. Mean step count difference between step activity monitor and manual tally was –4.8 steps (–1.8%). Intraclass correlation coefficients for step counts and 2-minute walk, standing balance, and 4-meter gait speed at discharge were 0.41 (95% CI –0.14 to 0.75), –0.12 (95% CI –0.67 to 0.64), and 0.17 (95% CI –0.46 to 0.66), respectively. Values were similarly poor at 30 days. ConclusionsThe use of consumer-grade Fitbit Charge HR in patients with recent mild stroke is feasible with reasonable adherence and accuracy. There was poor correlation between step counts and gait speed, balance, and endurance. Further research is needed to evaluate the association between step counts and other outcomes relevant to patients, including patient-reported outcomes and measures of physical function.