JMIR mHealth and uHealth (May 2024)

Monitoring Adolescent and Young Adult Patients With Cancer via a Smart T-Shirt: Prospective, Single-Cohort, Mixed Methods Feasibility Study (OncoSmartShirt Study)

  • Emma Balch Steen-Olsen,
  • Helle Pappot,
  • Maiken Hjerming,
  • Signe Hanghoej,
  • Cecilie Holländer-Mieritz

DOI
https://doi.org/10.2196/50620
Journal volume & issue
Vol. 12
pp. e50620 – e50620

Abstract

Read online

Abstract BackgroundWearables that measure vital parameters can be potential tools for monitoring patients at home during cancer treatment. One type of wearable is a smart T-shirt with embedded sensors. Initially, smart T-shirts were designed to aid athletes in their performance analyses. Recently however, researchers have been investigating the use of smart T-shirts as supportive tools in health care. In general, the knowledge on the use of wearables for symptom monitoring during cancer treatment is limited, and consensus and awareness about compliance or adherence are lacking. ObjectivesThe aim of this study was to evaluate adherence to and experiences with using a smart T-shirt for the home monitoring of biometric sensor data among adolescent and young adult patients undergoing cancer treatment during a 2-week period. MethodsThis study was a prospective, single-cohort, mixed methods feasibility study. The inclusion criteria were patients aged 18 to 39 years and those who were receiving treatment at Copenhagen University Hospital - Rigshospitalet, Denmark. Consenting patients were asked to wear the Chronolife ResultsA total of 10 patients were included. The number of days with wear times of >8 hours during the study period (14 d) varied from 0 to 6 (mean 2 d). Further, 3 patients had a mean wear time of >8 hours during each of their days with data registration. The number of days with any data registration ranged from 0 to 10 (mean 6.4 d). The thematic analysis of interviews pointed to the following three main themes: (1) the smart T-shirt is cool but does not fit patients with cancer, (2) the technology limits the use of the smart T-shirt, and (3) the monitoring of data increases the feeling of safety. Results from the questionnaire showed that the patients generally had confidence in the device. ConclusionsAlthough the primary end point was not reached, the patients’ experiences with using the smart T-shirt resulted in the knowledge that patients acknowledged the need for new technologies that improve supportive cancer care. The patients were positive when asked to wear the smart T-shirt. However, technical and practical challenges in using the device resulted in low adherence. Although wearables might have potential for home monitoring, the present technology is immature for clinical use.