Italian Journal of Food Safety (Jan 2011)

APPLICATION OF QUALITY INDEX METHOD (QIM) SCHEME IN SHELFLIFE STUDY OF ANGLERFISH (Lophius piscatorius)

  • L. Pennisi,
  • V. Olivieri,
  • R. D’Aurelio,
  • I. Piscione

DOI
https://doi.org/10.4081/ijfs.2011.1S.237
Journal volume & issue
Vol. 1, no. 1zero
pp. 237 – 241

Abstract

Read online

The aim was to evaluate a Quality Index Method (QIM) scheme for fresh Anglerfish (Lophius piscatorius). Anglerfish were stored at 0±2 °C on ice up to 9 days. Total Mesophilic Counts (TMC), Total Psychrophilic Counts (TPC) and counts of Specific Spoilage Organisms (SSOs) were done. An high correlation between the Quality Index (QI) and storage time on ice and between the Quality Index (QI) and H2S-producing bacteria counts was found. The remaining storage time could be estimated with accuracy of ±1.5 days when the Anglerfish were evaluated with QIM.

Keywords