Grasas y Aceites (Oct 1996)
Comparison of different solvents for determination of fat in liver
Abstract
The efficiency of different organic solvents for extraction the fat of pork and veal liver were compared. Soxhlet extraction for 8 hours with n-Hexane: dichloromethane (1:1) was selected. Cv% was 1.9%.