Journal of Cardiothoracic Surgery (Nov 2019)

TAVI-in-homograft (TiH): open transcatheter aortic valve replacement in calcified aortic homograft case reports

  • Marco Gennari,
  • Ilaria Giambuzzi,
  • Gianluca Polvani,
  • Marco Agrifoglio

DOI
https://doi.org/10.1186/s13019-019-1036-2
Journal volume & issue
Vol. 14, no. 1
pp. 1 – 3

Abstract

Read online

Abstract Background Redo surgery in patient who underwent aortic valve replacement with an aortic homograft can result technically challenging because of the massive calcification of the conduit. Case presentation We present a case of a patient who underwent open surgery on cardiopulmonary bypass assistance to implant a standard transcatheter aortic bioprosthesis through aortotomy in an off-label procedure and we discuss its safety and feasibility. Conclusions The combination of open cardiac surgery and open trans-aortic implant of a transcatheter prosthesis may reduce the surgical risk shrinking the technical difficulties that the implantation of a standard surgical prosthesis would have given.

Keywords